Practical lab · Access control
Access-control door logic
Fill in a truth table of door states and the events a controller reports.
Simulation — not real hardware
Simulation — not real hardware. Results are planning estimates from the formulas shown; real equipment, cabling and firmware differ. Check datasheets and site conditions before you buy or install.
What this lab covers
A single controlled door has a lock, a reader, a door position contact and a request-to-exit (REX) button. The controller watches them and reports events: a valid card releases the lock; the door opening without a valid card or REX is forced; an authorised opening left open past the held-open time is held.
Real controllers add schedules, anti-passback, interlocks and fire-alarm release. This exercise covers the core logic you need to read an event log.
Worked example
Door closed, nobody at the reader: Normal — door closed and locked.
Door contact opens but no card was read and REX was not pressed: the controller cannot tell who opened it, so it reports Door forced open — alarm — usually a missing REX on the inside, a mechanical key, or a door pushed open.
Try it
Talk to an engineer
Not sure which service fits?
Tell us what you are working on. A Foxnet engineer will point you to the right session, book or request — or tell you honestly if you do not need one.